Operating instructions
R4D280-CI03-01
Translation of the original operating instructions
3.2 Nominal data
Motor M4D110-IA
Phase 3~ 3~ 3~ 3~
Nominal voltage / VAC 230 277 400 480
Connection Δ Δ Y Y
Frequency / Hz 50 60 50 60
Type of data definition fa ml fa ml
Valid for approval /
standard
CE CE CE CE
Speed / min
-1
1330 1590 1330 1590
Power input / W 1320 1800 1320 1800
Current draw / A 4.75 5.12 2.75 2.96
Min. back pressure / Pa 0 250 0 250
Min. ambient temperature
/ °C
-25 -25 -25 -25
Max. ambient
temperature
/ °C
65 45 65 45
Maximum safe operating
speed / min
-1
2730 2730 2730 2730
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category A
Efficiency category Static
Variable speed drive No
Specific ratio
*
1.01
*
Specific ratio = 1 + pfs / 100 000 Pa
Actual Request
2013
Request
2015
Overall efficiency ηes / % 36.1 29 36
Efficiency grade N 44.1 37 44
Power input Pe / kW 0.55
Air flow qv / m³/h 1445
Pressure increase total psf / Pa 500
Speed n / min
-1
1440
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass 12 kg
Size 280 mm
Surface of rotor Cast in aluminium
Material of impeller Sheet steel, hot-dip galvanised
Direction of rotation Clockwise, seen on rotor
Type of protection IP 54
Insulation class "F"
Humidity class F3-1
Mounting position Shaft horizontal or rotor on bottom; rotor
on top on request
Condensate discharge
holes
Rotor-side
Operation mode S1
Motor bearing Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Motor protection Thermal overload protector (TOP)
brought out
Protection class I (if protective earth is connected by
customer)
Product conforming
to standard
EN 61800-5-1; CE
Approval CSA C22.2 Nr.100; EAC; UL 1004-1;
VDE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+80 °C
Min. permissible
ambient motor temp.
(transp./storage)
-40 °C
Item no. 10716-5-9970 · Revision 82542 · Release 2014-05-08 · Page 5 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 ·
[email protected] · www.ebmpapst.com
Comentários a estes Manuais